  Datasheet File OCR Text:
  features surge overload rating -280 amperes peak ideal for printed circuit board reliable low cost construction utilizing molded plastic technique plastic material has u/l flammability classification 94v-0 mounting postition:any maximum ratings and electrical characteristics kbu kbu kbu kbu kbu kbu kbu 20005g 2001g 2002g 2004g 2006g 2008g 2010g maximum recurrent peak reverse voltage v rrm 50 100 200 400 600 800 1000 v maximum rms voltage v rms 35 70 140 280 420 560 700 v maximum dc blocking voltage v dc 50 100 200 400 600 800 1000 v maximum average forward (with heatsink note 1) rectified current @ t c =100 peak forward surge current 8.3ms single half sine-wave super imposed on rated load (jedec method) maximum forward voltage at 10 a dc v f v maximum dc reverse current @ t j =25 at rated dc blocking voltage @ t j =125 operating temperature range t j storage temperature range t stg notes: 1.device mounted on 100mm*100mm*1.6mm cu plate heatsink. -55 to +150 -55 to +150 rev. 2, 16-mar-2017 i r 10 a 500 i fsm 280 a 1.1 characteristics symbol unit i (av) 20 a dimensions in inches and (milimeters) rating at 25 ambient temperature unless otherwise specified. single phase, half wave ,60hz, resistive or inductive load. for capacitive load, derate current by 20% kbu20005g thru kbu2010g glass passivated reverse voltage - 50 to 1000 volts forward current - 20.0 amperes bridge rectifiers kbu .935(23.7) .895(22.7) .600(16.8) .700(17.8) 300 (7.5) .780(19.8) .740(18.8) (25.4) 1.00 min. .052(1.3)dia. .048(1.2)typ. .071(1.8) .087(2.2) .220(5.6) .180(4.6) .256(6.5) .276(7.0) .15 x23l (3.8 x5.7l) hole thru .157(4.0)*45
rating and characteristic curves kbu20005g thru kbu2010g the curve graph is for reference only, can't be the basis for judgment( ?)! rev. 2, 16-mar-2017 fig.4? typical reverse characteristics percent of rated peak reverse voltage instantaneous reverse current microamperes t j = 25 c 0.01 0.1 1.0 10 140 120 100 806040 20 0 case temperature ( c) fig. 2 ? derating curve output rectified current average forward output current amperes 50 20 10 5 0 15 100 150 fig.1-maximum forward surge current number of cyclets at 60hz peak forward surge current amperes 1 10 100 0 350 200 150 100 50 250 300 0 0.2 0.4 0.6 0.8 1.2 1.61.4 1.0 1.8 100 10 0.1 1.0 instantaneous forward voltage,volts fig.3-typical forward characteristics instantaneous forward current, (a) 0 0.2 0.4 0.6 0.8 1.2 1.61.4 1.0 1.8 100 10 0.1 1.0
legal disclaimer notice all specifications and data are subject to be changed without notice to improve reliability function or design or other reasons. hy makes no warranty, representation or guarantee regarding the suitability of the products for any particular purpose or the co- tinuing production of any product. to the maximum extent permitted by applicable law, hy disclaims (i) any and all liability arising out of the application or use of any product, (ii) any and all liability, including without limitation special,consequential or incidental d- amages, and (iii) any and all implied warranties, including warranties of fitness for particular purpose, non-infringement and merch- antability. statements regarding the suitability of products for certain types of applications are based on hy?s knowledge of typical require- ments that are often placed on hy products in generic applications. such statements are not binding statements about the suitabi- lity of products for a particular application. it is the customer?s responsibility to validate that a particular product with the properties described in the product specification is suitable for use in a particular application.parameters provided in datasheets and specific- ations may vary in different applications and performance may vary over time. all operating parameters, including typical paramet- ers, must be validated for each customer application by the customer?s technical experts. product specifications do not expand or otherwise modify hy?s terms and conditions of purchase, including but not limited to the warranty expressed therein. except as expressly indicated in writing, hy products are not designed for use in medical, life-saving, or life-sustaining applicati- ons or for any other applications in which the failure of the hy product could result in personal injury or death. customers using or selling hy products not expressly indicated for use in such applications do so at their own risk.please contact authorized hy pers- onnel to obtain written terms and conditions regarding products designed for such applications. no license, express or implied, by estoppel or otherwise, to any intellectual property rights is granted by this document or by any conduct of hy. product names and markings noted herein may be trademarks of their respective owners. ?????????? hy ???????????hy (i) ? ??????(ii) ???????(iii) ??? ???????? ????? hy ? hy ???????????? ???????????????? ????? ????????????? ??? hy ???? hy ???? ?hy ????? hy ??????? ?????? hy ????????hy ?? ? ? hy ??????????????????? ??? rev. 2, 16-mar-2017 disclaimer


▲Up To Search▲   

 
Price & Availability of KBU2008G

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X